REX12D-TA1-100-DC24V-10A ETA Electronic circuit breaker

Electronic overcurrent circuit breaker
1-channel
Rated current 10A
€50.72
  • Buy 10 for €48.34 each and save 5%
  • Buy 25 for €44.38 each and save 13%
  • Buy 50 for €40.81 each and save 20%
  • Buy 100 for €39.62 each and save 22%
Incl. 19% Tax, plus Shipping
Delivery within 1 to 3 days within Germany.
In stock
SKU
24-01831
REX12D-TA1-100-DC24V-10A ETA Electronic circuit breaker is available to buy in increments of 1
Zubehör

Artikel dem Warenkorb hinzufügen oder Alles auswählen

The compact and flexible REX all-in-one solution consists of numerous coordinated components. These range from the EM12D-T/EM12-T power supply modules for the positive and negative potential to the REX12D-T electronic circuit breakers, which can be connected in any modular fashion on one or two channels, and the PM12-T potential expansion modules for positive and negative duplication.

With the intelligent REX12D fuse system and the EM12D interface modules, E-T-A provides the ideal solution for mechanical engineering. It combines the proven quality of DC 24 V overcurrent protection with the communication capability of the IO-Link and Modbus RTU system. This enables complete transparency of the DC 24 V power supply and thus provides the necessary information for a stable production process in this system area.

The modular devices, which are only 12.5 mm wide and can be arranged in rows, are designed entirely in push-in technology including pusher, thus enabling tool-free, time-saving and maintenance-free wiring. No additional accessories are required for the electrical and mechanical connection of the individual components. This saves time and money!



Key features:

  • Control, diagnostics and monitoring via IO-Link and Modbus RTU
  • Device combination of supply modules, overcurrent protection and power distribution
  • Selective load protection by means of electronic switch-off characteristic
  • No accessories required to connect the components
  • Width per channel 6.25 mm (2-channel)
  • Fixed and variable rated currents 1 A-10 A
  • Integrated fail-safe element, precisely matched to the maximum rated current
  • Switching on capacitive loads up to 20,000 μF
  • Manual ON/OFF/reset button
  • Connection via push-in terminals incl. terminal actuator

Technical data:

operating data
operating voltage UB dC 24 V (18...30 V)

rated currentIN
REX12D-TA1
REX12D-TA2
REX12D-TE2

current ratings:
8 A, 10 A,
1 A/1 A, 2 A/2 A, 3 A/3 A, 4 A/4 A, 6 A/6 A
1 A - 10 A Delivery status max. rated current
quiescent current I0 in ON state: typ. 20...30 mA depending on signal output
visual signalling of the
operating status via multicoloured
indicator light:

green:
Load circuit controlled
Green/orange:
flashing: - Load current warning limit 50 % - 100 % reached

orange:
- overload or short-circuit until switch-off
- circuit breaker has been switched off by the higher-level control system,
LED is permanently orange

red:
- after an overload / short-circuit switch-off
- in the event of an undervoltage switch-off of the operating voltage in the ON state
with automatic restart

oFF:
Device switched off via the ON/OFF button, lack of operating voltage
or incorrect initialisation of the circuit breaker

load circuit
load output power MOSFET switching output (positive switching)

overload switch-off (IÜL)


with switch-off times (tÜL)

short-circuit switch-off time (tKS)

typ. IÜL: IN x 1.05 tÜL: 3 s
typ. IÜL: IN x 1.35 tÜL: 0.5 s

typ. IÜL: IN x 2.00 tÜL: 0.1 s
typ. ION: IN x 2.50 tOIL: 0.012 s

typ. with short circuit (IKS) tKS: 0.002 s2)
switch-off time (tKS) see time / current characteristic curve

housing material plastic
enclosure mounting mounting rail to EN 60715-35x7.5
ambient temperature (TU) -25 °C...+60 °C
(without condensation, see EN 60204-1)
storage temperature -40 °C...+70 °C
installation temperature +5 °C...+60 °C
humidity Heat 96 hours/95 % relat. Humidity/40 °C in accordance with
IEC 60068-2-78-Cab Climate class 3K3
in accordance with EN 60721
vibration resistance 5 g, test according to IEC 60068-2-6 Test Fc
protection class iEC 60529, DIN VDE 0470
IP30
eMC requirements
(EMC Directive, CE marking)
interference emission: EN 61000-6-3
Interference immunity: EN 61000-6-2
insulation coordination
(IEC 60934)
0.5 kV / pollution degree 2
dielectric strength max. DC 30 V (load circuit)
insulation resistance (off state) not applicable, only electronic switch-off


Approval:

test centre test standard File no. rated voltage rated current range
uL uL 2367 E306740 dC 24 V 1 A...10 A
uL

uL 1310
NEC Class2

E306740 dC 24 V

1 A, 2 A,
3 A, 4 A

uL

uL60947 / cULus508listed

e492388

dC 24 V

1 A...10 A

More Information
Item name REX12D-TA1-100-DC24V-10A ETA Electronic circuit breaker
SKU 24-01831
Weight 0.055900
Version 1 ohne galvanische Trennung
Design: Communication, interface 01 analog Signal
Country of manufacture Germany
Signal output 0 without signal output
Connection type Main connections P10 flat plug DIN 46244-A6.3-0.8
Series REX12
Design A 1 load output terminal per channel, fixed current xA or xA/xA
Signal input 0 without signal input
Actuating element Manual ON/OFF/Reset button
Undervoltage module none
Operating voltage DC 24 V
Number of poles 1-pole thermally protected
Rated current range 10A
Mounting type T Mounting rail fastening
Characteristic Medium time-lag tripping characteristic (standard)
Additional function 0 ohne
Number of channels 1 1 channel (only 1 channel)
Traub order number REX12D-TA1-100-DC24V-10A
Commodity code 85362010
Manufacturer E-T-A